• facebook
  • linkedin
  • Instagram
  • youtube
  • WhatsApp
  • nybjtp

OEM High Quality Multifunction Meter Supplier - Active and Reactive Frequency Table (Design Paragraph) – Newlink

Short Description:


Product Detail

Video

Product Tags

Related Video

Feedback (2)

With advanced technologies and facilities, strict good quality manage, reasonable rate, superior assistance and close co-operation with shoppers, we have been devoted to supplying the very best price for our consumers for Ac And Dc Multirange Ammeter, Digital High Voltage Meter, 3 Phase Motor Thermal Protection, Living by quality, development by credit is our eternal pursuit, We firmly believe that after your visit we will become long-term partners.
OEM High Quality Multifunction Meter Supplier - Active and Reactive Frequency Table (Design Paragraph) – Newlink Detail:

Intelligent digital display Power Meter Instruction Manual

Overview

This series of intelligent digital display power meter is a high-precision meter developed for power measurement and display in power grid and automatic control system. It has the advantages of intuitive display, high precision, good stability and strong vibration resistance. CPU digital processing, AC true RMS measurement, CT (PT) can be set through the panel keys. Optional: 1 relay control output, can be set to: upper limit; lower limit; upper and lower limit, 2 digital output, RS485 communication interface, using standard Modbus-RTU protocol, can be directly connected with industrial configuration software, easy to group network, 3. All the way analog output.

product-description1

product-description2

Operating Instructions

1. key definition

Function key SET: It is used to enter the menu, and it is the confirmation key in programming mode.

Shift key: Cycle through the nixie tubes in the selected page, and the selected nixie tubes are flashing.

Increase key ▲: Enter the setting value, change the value of the flashing digital tube (the numbers cycle from 0 to 9).

2. Operation method

Use the menu key SET to select the setting page, use the increase key ▲ to enter the setting value setting, use the shift key and the increase key ▲ to change the digital tube value on the page, adjust to the desired value and press the function key SET to confirm and exit the programming state.

Single/Three Phase Power Factor Meter Instruction Manual

Features

1. Single-phase and three-phase can be set through the panel buttons

2. Display range: C0.000~1.000~L0.000

3. Software adjustment, no internal potentiometer, high precision

4. Optional with communication function. (must be specified when ordering)

5. Optional with upper and lower limit alarm control function

Instructions

1. Press and hold the SET button for 6 seconds to enter the menu, the r-H (for setting direct reading parameters) mark appears, and then press SET again to enter the set value (0005), this value is the displayed value (ie the base value), this You can use the up key “△” to change the large value, and you can also use the down key “▽” to change the small value. Press the SET key again to display the r-K (set magnification) mark, and press SET again to enter the set value (0001). At this time, you can use the up key “△” to change the large value, and you can also use the down key “▽” to change the small value.

Note: If it is a simple function, after completing the operation through the above keys, press the SET key continuously to exit.

2. If you want additional functions, you can continue to complete the operation through the following keys:

Press the SET key again to display the Addr (communication address) sign, and press SET again to enter the set value (0001). At this time, you can use the up key “△” to change the large value, or use the down key “▽” to change the decimal value. Press the SET key again to display the BAUD (baud rate) mark, and press SET again to enter the set value (9600). At this time, you can use the up key “△” to change the large value, or use the down key “▽” to change the decimal value . Press the SET button again to display the ALHL (alarm) sign, press SET again to enter the upper limit alarm setting (AH-Y), if you want to set the lower limit alarm, you can press the up button “△” again to enter the lower limit alarm setting (AL-Y) ), then press SET to display the (ALN) sign, then press SET again to enter the alarm value setting menu (2000). At this time, you can use the up key “△” to change the larger value, or press the down key “▽” Change the decimal value.

Matters needing attention

1. Before use, the meter needs to be powered on for 15 minutes.

2. Pay attention to prevent vibration and impact, and do not use it in places with excess dust and excess harmful gases.

3. The input wire should not be too long. If the input end of the signal under test is long, please use a twisted pair shielded wire.

4. If the signal is accompanied by high frequency interference, a low frequency filter should be used in the line.

5. When not in use for a long time, please turn on the power for no less than 4 hours every three months.

6. Long-term storage should avoid direct light, and should be stored at -10℃~70℃.

7. If there is no display on the meter, first check the auxiliary power supply to see if the voltage is within the specified range.

8. If the display is abnormal, check whether the input signal is normal and whether the signal terminals are tightened.

9. Unless the PT has enough power, the PT signal cannot be used as an auxiliary power supply at the same time to ensure the normal operation of the instrument.

10. The screws of the current terminals in the CT circuit must be tightened to ensure reliable contact between the incoming and outgoing wires to avoid malfunctions.

11. To calibrate the instrument, the calibration instrument should be better than level 0.1 to ensure the calibration accuracy.

Product In Kind

product-description3

External Dimensions

product-description4


Product detail pictures:

OEM High Quality Multifunction Meter Supplier - Active and Reactive Frequency Table (Design Paragraph) – Newlink detail pictures


Related Product Guide:

We believe that long expression partnership is often a result of top of the range, value added service, prosperous encounter and personal contact for OEM High Quality Multifunction Meter Supplier - Active and Reactive Frequency Table (Design Paragraph) – Newlink , The product will supply to all over the world, such as: Manchester, Slovakia, New Orleans, Adhering to the principle of Enterprising and Truth-Seeking, Preciseness and Unity, with technology as the core, our company continues to innovate, dedicated to providing you with the highest cost-effective solutions and meticulous after-sales service. We firmly believe that: we're outstanding as we have been specialized.
  • High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Hedy from Libya - 2017.10.27 12:12
    We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By Juliet from Ottawa - 2017.02.14 13:19
    Write your message here and send it to us

    Related products

    • OEM High Quality Mini Digital Voltmeter Suppliers - Single Phase Voltmeter (Conventional) – Newlink

      OEM High Quality Mini Digital Voltmeter Supplie...

      Overview The smart voltmeter adopts AC sampling technology, can measure the voltage in the power grid, and can set the magnification through the panel buttons, which is very cost-effective. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: s...

    • ODM Dc Volt Amp Meter With Shunt Factories - Single-phase Ammeter (Conventional) – Newlink

      ODM Dc Volt Amp Meter With Shunt Factories - S...

      Overview The smart ammeter adopts AC sampling technology, which can measure the current in the power grid. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: single-phase current Display: a row of LED digital / LCD liquid crystal display Uses: suitable...

    • OEM High Quality Analog Micro Amp Meter Factories - Three -Phase Voltage Table (Design Model) – Newlink

      OEM High Quality Analog Micro Amp Meter Factori...

      Overview Using AC voltage technology, it is possible to measure the three voltage phases in the power grid, and simply compare them through the panel setting rate. Features, and can complete the network communication with similar PLC and industrial computer. Features Measurement: Three-phase voltage Display: Three rows of LED digital / LCD liquid crystal display A, B, C three-phase voltage Uses: suitable for power grid, automatic control system. Low-voltage three-phase current measurement cir...

    • OEM High Quality 3 Phase Motor Protection Circuit Suppliers - Common Type Temperature And Humidity Controller – Newlink

      OEM High Quality 3 Phase Motor Protection Circu...

      Application

    • OEM High Quality Wall Mounted Dehumidifier Supplier - Intelligent Temperature And Humidity Controller – Newlink

      OEM High Quality Wall Mounted Dehumidifier Supp...

      Application

    • ODM Dc Ammeter Digital Manufacturer - Digital LED Timer – Newlink

      ODM Dc Ammeter Digital Manufacturer - Digital ...

      Shape     working power supply A type DC5V ±5%S150mAAC/DC9-12V B type DC5V±5%≤150mA AC/DC9v-220V AC110-220V DC5V±5%≤150mA AC/DC9v-220V AC110-220V Dimensions (width × height × depth mm) 79×42.5×25.5(A)79×42.5×58(B) 74×32×69 Mounting Hole(mm) 76×39.5 70×28 Basic range Customized on request Customized on request Measurement precision ≤0.1% ≤0.1% Input Contact signal or standard TTL high and low level signal Contact signal or standard TTL high and low level signal Display method ...