We have now sophisticated machines. Our solutions are exported to the USA, the UK and so on, enjoying a great reputation amid consumers for Voltmeter Panel Meter, Smart Dehumidifier, Wifi Energy Meter, In addition, we would properly guide the customers about the application techniques to adopt our products and the way to select appropriate materials.
OEM High Quality High Current Dc Ammeter Factories - Active and Reactive Frequency Table (Design Paragraph) – Newlink Detail:

Intelligent digital display Power Meter Instruction Manual

Overview

This series of intelligent digital display power meter is a high-precision meter developed for power measurement and display in power grid and automatic control system. It has the advantages of intuitive display, high precision, good stability and strong vibration resistance. CPU digital processing, AC true RMS measurement, CT (PT) can be set through the panel keys. Optional: 1 relay control output, can be set to: upper limit; lower limit; upper and lower limit, 2 digital output, RS485 communication interface, using standard Modbus-RTU protocol, can be directly connected with industrial configuration software, easy to group network, 3. All the way analog output.

product-description1

product-description2

Operating Instructions

1. key definition

Function key SET: It is used to enter the menu, and it is the confirmation key in programming mode.

Shift key: Cycle through the nixie tubes in the selected page, and the selected nixie tubes are flashing.

Increase key ▲: Enter the setting value, change the value of the flashing digital tube (the numbers cycle from 0 to 9).

2. Operation method

Use the menu key SET to select the setting page, use the increase key ▲ to enter the setting value setting, use the shift key and the increase key ▲ to change the digital tube value on the page, adjust to the desired value and press the function key SET to confirm and exit the programming state.

Single/Three Phase Power Factor Meter Instruction Manual

Features

1. Single-phase and three-phase can be set through the panel buttons

2. Display range: C0.000~1.000~L0.000

3. Software adjustment, no internal potentiometer, high precision

4. Optional with communication function. (must be specified when ordering)

5. Optional with upper and lower limit alarm control function

Instructions

1. Press and hold the SET button for 6 seconds to enter the menu, the r-H (for setting direct reading parameters) mark appears, and then press SET again to enter the set value (0005), this value is the displayed value (ie the base value), this You can use the up key “△” to change the large value, and you can also use the down key “▽” to change the small value. Press the SET key again to display the r-K (set magnification) mark, and press SET again to enter the set value (0001). At this time, you can use the up key “△” to change the large value, and you can also use the down key “▽” to change the small value.

Note: If it is a simple function, after completing the operation through the above keys, press the SET key continuously to exit.

2. If you want additional functions, you can continue to complete the operation through the following keys:

Press the SET key again to display the Addr (communication address) sign, and press SET again to enter the set value (0001). At this time, you can use the up key “△” to change the large value, or use the down key “▽” to change the decimal value. Press the SET key again to display the BAUD (baud rate) mark, and press SET again to enter the set value (9600). At this time, you can use the up key “△” to change the large value, or use the down key “▽” to change the decimal value . Press the SET button again to display the ALHL (alarm) sign, press SET again to enter the upper limit alarm setting (AH-Y), if you want to set the lower limit alarm, you can press the up button “△” again to enter the lower limit alarm setting (AL-Y) ), then press SET to display the (ALN) sign, then press SET again to enter the alarm value setting menu (2000). At this time, you can use the up key “△” to change the larger value, or press the down key “▽” Change the decimal value.

Matters needing attention

1. Before use, the meter needs to be powered on for 15 minutes.

2. Pay attention to prevent vibration and impact, and do not use it in places with excess dust and excess harmful gases.

3. The input wire should not be too long. If the input end of the signal under test is long, please use a twisted pair shielded wire.

4. If the signal is accompanied by high frequency interference, a low frequency filter should be used in the line.

5. When not in use for a long time, please turn on the power for no less than 4 hours every three months.

6. Long-term storage should avoid direct light, and should be stored at -10℃~70℃.

7. If there is no display on the meter, first check the auxiliary power supply to see if the voltage is within the specified range.

8. If the display is abnormal, check whether the input signal is normal and whether the signal terminals are tightened.

9. Unless the PT has enough power, the PT signal cannot be used as an auxiliary power supply at the same time to ensure the normal operation of the instrument.

10. The screws of the current terminals in the CT circuit must be tightened to ensure reliable contact between the incoming and outgoing wires to avoid malfunctions.

11. To calibrate the instrument, the calibration instrument should be better than level 0.1 to ensure the calibration accuracy.

Product In Kind

product-description3

External Dimensions

product-description4


Product detail pictures:

OEM High Quality High Current Dc Ammeter Factories - Active and Reactive Frequency Table (Design Paragraph) – Newlink detail pictures


Related Product Guide:

We now have our individual sales group, layout team, technical team, QC crew and package group. Now we have strict high-quality control procedures for each procedure. Also, all of our workers are experienced in printing discipline for OEM High Quality High Current Dc Ammeter Factories - Active and Reactive Frequency Table (Design Paragraph) – Newlink , The product will supply to all over the world, such as: France, Hungary, Georgia, If you give us a list of merchandise you are interested in, along with makes and models, we can send you quotations. Remember to email us directly. Our goal is to establish long-term and mutually profitable business relationships with domestic and overseas clients. We look forward to receiving your reply soon.
  • The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
    5 Stars By Brook from Puerto Rico - 2018.09.12 17:18
    Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Penny from New Delhi - 2017.11.20 15:58
    Write your message here and send it to us

    Related products

    • OEM High Quality Portable Electric Meter Suppliers - Digital LED Timer – Newlink

      OEM High Quality Portable Electric Meter Suppli...

      Shape     working power supply A type DC5V ±5%S150mAAC/DC9-12V B type DC5V±5%≤150mA AC/DC9v-220V AC110-220V DC5V±5%≤150mA AC/DC9v-220V AC110-220V Dimensions (width × height × depth mm) 79×42.5×25.5(A)79×42.5×58(B) 74×32×69 Mounting Hole(mm) 76×39.5 70×28 Basic range Customized on request Customized on request Measurement precision ≤0.1% ≤0.1% Input Contact signal or standard TTL high and low level signal Contact signal or standard TTL high and low level signal Display method ...

    • OEM High Quality Dc Motor Overload Protection Supplier - Intelligent Temperature And Humidity Controller – Newlink

      OEM High Quality Dc Motor Overload Protection S...

    • OEM High Quality Wattmeter And Energy Meter Suppliers - Multifunctional Power Meter (Conventional) – Newlink

      OEM High Quality Wattmeter And Energy Meter Sup...

      Overview The multi-function power meter can measure all the commonly used power parameters in the three-phase power grid system with high precision: three-phase voltage, three-phase current, active power, reactive power, power factor, grid frequency, active energy, reactive energy, and with Communication interface and power pulse output function. Adopt MODBUS-RTU communication protocol to realize LED/LCD on-site display and remote RS-485 digital communication. It has the characteristics of co...

    • ODM Voltmeter Panel Meter Factories - Single-Phase Multi-Function Power Meter (Design Version) – Newlink

      ODM Voltmeter Panel Meter Factories - Single-P...

      Overview The single-phase multi-function meter can measure all the commonly used power parameters in the power grid system with high precision: single-phase voltage, single-phase current, active power, reactive power, power factor, grid frequency, active energy, reactive energy, and with communication Interface and energy pulse output function. Adopt MODBUS-RTU communication protocol to realize LED/LCD on-site display and remote RS-485 digital communication. It has the characteristics of conv...

    • OEM High Quality Wifi Electric Meter Factories - Single-Phase Current (Design Version) – Newlink

      OEM High Quality Wifi Electric Meter Factories ...

      Overview The smart ammeter adopts AC sampling technology, which can measure the current in the power grid. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: single-phase current Display: a row of LED digital / LCD liquid crystal display Uses: suitable...

    • OEM High Quality Power And Energy Meter Factory - Active and Reactive Frequency Table (Design Paragraph) – Newlink

      OEM High Quality Power And Energy Meter Factory...

      Intelligent digital display Power Meter Instruction Manual Overview This series of intelligent digital display power meter is a high-precision meter developed for power measurement and display in power grid and automatic control system. It has the advantages of intuitive display, high precision, good stability and strong vibration resistance. CPU digital processing, AC true RMS measurement, CT (PT) can be set through the panel keys. Optional: 1 relay control output, can be set to: upper limit...