• facebook
  • linkedin
  • Instagram
  • youtube
  • WhatsApp
  • nybjtp

ODM Digital Dc Voltmeter And Ammeter Factory - LED Digital Display Meter – Newlink

Short Description:


Product Detail

Video

Product Tags

Related Video

Feedback (2)

We insist on the principle of development of 'High quality, Efficiency, Sincerity and Down-to-earth working approach' to provide you with excellent service of processing for Fiber Meter, Solar Energy Monitor, Dc Differential Voltmeter, Our purpose is always to build Win-win scenario with our customers. We feel we are going to be your greatest choice. Reputation To start with, Buyers Foremost. Waiting for your inquiry.
ODM Digital Dc Voltmeter And Ammeter Factory - LED Digital Display Meter – Newlink Detail:

ltem/Model (Emerald Backlight) (white backight optional negative display white characters)
Shape  1  2
Working power DC5V±5%≤15mA
AC/DC9V-12V AC/DC24V
DC5V±5%≤15mA
AC/DC9V-12V AC/DC24V
Dimensions (WwH’Dmm) 79×42.5×25.5 79×42.5×25.5
Mounting hole(mm) 75×39.5 75×39.5
Measurement accuracy ±0.2% of full scale value ±2 words(DC)
+0.5% full scale value ±5 words (AC)
±0.2% of full scale value +2 words(DC)
±0.5% full scale value 15 words(AC)
Basic rangeo DC voltage (direct input) 200mV/2V/20V/200V/500V 200mV/2V/20V/200V/500V
AC voltage(direct input) 200mV/2V/20V/200V/300V 200mV/2V/20V/200V/300V
DC current (dired input) 200μA/2mA/20mA/200mA/2A/5A 200μA/2mA/20mA/200mA/2A/5A
AC current (direct input) 200μA/2mA/20mA/200mA/2A/5A 200μA/2mA/20mA/200mA/2A/5A
Extended range (external input) AC transfomer. DC shunt Voltage drop module AC transfomer. DC shunt Voltage drop module
Display character height 20×10mm LCD show 20× 10mm LCD show
Features Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation
Other +/-polarity automatic switching, optional reading lock function +/-polarity automatic switching, optional reading lock function
ltem/Model (negative emerald green characters) (Negatve white characters can be selected with white backlight)
Shape  1  2
Working power DC5V±5%≤15mA
AC/DC9V-12V AC/DC24V
DC5V±5%≤15mA
AC/DC9V-12V AC/DC24V
Dimensions (WwH’Dmm) 79×42.5×25.5 79×42.5×25.5
Mounting hole(mm) 75×39.5 75×39.5
Measurement accuracy ±0.2% of full scale value ±2 words(DC)
+0.5% full scale value ±5 words (AC)
±0.2% of full scale value +2 words(DC)
±0.5% full scale value 15 words(AC)
Basic rangeo DC voltage (direct input) 200mV/2V/20V/200V/500V 200mV/2V/20V/200V/500V
AC voltage(direct input) 200mV/2V/20V/200V/300V 200mV/2V/20V/200V/300V
DC current (dired input) 200μA/2mA/20mA/200mA/2A/5A 200μA/2mA/20mA/200mA/2A/5A
AC current (direct input) 200μA/2mA/20mA/200mA/2A/5A 200μA/2mA/20mA/200mA/2A/5A
Extended range (external input) AC transfomer. DC shunt Voltage drop module AC transfomer. DC shunt Voltage drop module
Display character height 20×10mm LCD show 20× 10mm LCD show
Features Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation
Other +/-polarity automatic switching, optional reading lock function +/-polarity automatic switching, optional reading lock function

If the power supply DC5V is used to measure AC300V or AC500V, it is recommended to use the power supply AC9V to measure AC300V or AC500V, which saves 30%-50% of production costs.

(Blue backlight optional negative blue words) (Orange backlight optional negative orange word) (Red backlight optional negative red words) (negative green words)
 1  2  3  4
DC5V±5%≤15mA AC/DC9v-12V AC/DC24V DC5V±5%≤15mA AC/DC9v-12V AC/DC24V DC5V±5%≤15mA AC/DC9v-12V AC/DC24V DC5V±5%≤15mA AC/DC9v-12V AC/DC24V
79×42.5×25.5 79×42.5×25.5 79×42.5×25.5 79×42.5×25.5
75×39.5 75×39.5 75×39.5 75×39.5
±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC)
±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC)
200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V
200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V
200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
20×10mm LCD display 20×10mm LCD display 20×10mm LCD display 20×10mm LCD display
Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation
+/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function
(negative blue characters, optional blue backlight) (Negative orange characters, optional orange backlight) (negative red words, backlight optional red) (green backlight word)
 5  6  7  8
DC5V±5%≤15mA AC/DC9C-220V AC110-220V DC5V±5%≤15mA AC/DC9C-220V AC110-220V DC5V±5%≤15mA AC/DC9C-220V AC110-220V DC5V±5%≤15mA AC/DC9C-220V AC110-220V
79×42.5×58 79×42.5×58 79×42.5×58 79×42.5×58
75×39.5 75×39.5 75×39.5 75×39.5
±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC)
±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC)
200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V
200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V
200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
20×10mm LCD display 20×10mm LCD display 20×10mm LCD display 20×10mm LCD display
Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation
+/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function

Recommendation: The digital AC ammeter is in the measurement range of 10A-300A, and it is recommended to use a precision current transformer (see pages 49-51 for technical specifications). The production cost can be saved by 30%-50%.

3 and a half LED digital display meter product selection

The main technical parameters

Shape  1  2
Working power DC5V±5%≤ 100mA AC/DC9V-12V AC/DC24V-48V DC5V±5%≤ 100mA AC/DC9V-220V AC110-220V
Dimensions (W’H’Dmm) 79×42.5×25.5 79×42.5×58
Mounting hole(mm) 76×39.5 76×39.5
Measurement accuracy ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC)
Basic range DC voltage (direct input) 200mv / 2V / 20V / 200V / 500V 200mv / 2V / 20V / 200V / 500V
AC voltage(direct input) 200mv / 2V / 20V / 200V / 300V 200mv / 2V / 20V / 200V / 500V
DC current (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 10A
ACcurrent (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 10A
Extended range (external input) AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
Display character height 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue)
Features Fully enclosed gray shell, curved design, embedded installation Fully enclosed gray shell, curved design, embedded installation
Other +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function
Shape  1  2
Working power DC5V±5%AC/DC9V-12V AC/DC24V DC5V±5%≤ 100mA
Dimensions (W’H’Dmm) 48×26×35 48×26×23
Mounting hole(mm) 47×23 47×23
Measurement accuracy ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 digits (DC)
Basic range DC voltage (direct input) 200mv / 2V / 20V / 200V / 500V 200mv / 2V / 20V / 200V
AC voltage(direct input) 200mv / 2V / 20V / 200V / 300V
DC current (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA
ACcurrent (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A
Extended range (external input) AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
Display character height 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue)
Features Delicate appearance, small and exquisite, embedded design Delicate appearance, small and exquisite, embedded design
Other +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function

If the power supply DC5V is used to measure AC300V or AC500V, it is recommended to use the power supply AC9V to measure AC300V or AC500V, which saves 30%-50% of production costs.

 1  2  3  4
DC5V±5%≤100mA AC/DC9V-12V DC5V±5%≤100mA AC/DC9V-220V AC110-220V DC5V±5%AC/DC9V-12V AC/DC24V DC5V±5%≤100mA
71×40×28 71×40×58 46×26×20 48×29×30
68×38 68×38 42×23 46×265
±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC)
200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V
200mV / 2V / 20V / 200V /300V 200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /300V 200mV / 2V / 20V / 200V /300V
200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/10A 200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A
200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/10A 200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue)
Fully enclosed gray shell, curved design, embedded installation The shell size is the same as that of the 85L/85C series pointer head, which can be directly interchanged Exquisite shape, small and exquisite, embedded design Exquisite shape, small and exquisite, embedded design
+/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function
 1  2  3
DC5V±5%≤100mA AC/DC9V-12V DC5V±5%≤100mA AC/DC9V-12V DC5V±5%≤100mA AC/DC9V-220V AC110-220V
72×36×20 79×42.5×20 74×32×69
69×34 76×39.5 70×28
±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC)
200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V
200mV / 2V / 20V / 200V /300V 200mV / 2V / 20V / 200V /300V 200mV / 2V / 20V / 200V /300V
200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A
200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue)
Plug-in self-locking device, easy to install Black shell, embedded installation, elegant appearance Fully enclosed gray housing, flat design, ejector clamp installation
+/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function

Recommendation: The digital AC ammeter is in the measurement range of 10A-300A, and it is recommended to use a precision current transformer (see pages 49-51 for technical specifications). The production cost can be saved by 30%-50%.

4 and a half LED digital display meter product selection

The main technical parameters

Shape  product description1  product description2
Working power DC5V±5%≤150mA DC5V土5% S 150mA AC/DC9V-12V AC/DC24V-48V
Dimensions (W’H'Dmm) 79×42.5×25.5 79×42.5×58
Mounting hole(mm) 76×39.5 76×39.5
Measurement accuracy ±0.03% full scale value ±2 words(DC) ±0.03% full scale value ±2 words(DC) ±0.5% full scale value ±35 words(AC)
Basic range DC voltage (direct input) 200mV/2V/20V/200V/500V 200mV/2V/20V/200V/500V
AC voltage(direct input) 200mV/2V/20V/200V/500V
DC current (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
ACcurrent (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A
Extended range (external input) DC shunt, voltage drop module AC Transformer, DC Shunt,Voltage Drop Modu
Display character height 0.56LED red(optional green,yellow or blue)
Features Totally enclosed gray shell, curved design, embedded installation
Other +/-polarity automatic switching, optional reading lock function
Shape

product description3

product description4

Working power DC5V±5%≤150mA AC/DC9V-220V AC110-220V DC5V±5%≤150mA AC/DC9V-220V AC110-220V
Dimensions (width x height x depth mm) 96×48×86 96×48×117
Mounting Hole(mm) 90×45 91×44
Measurement precision ±0.5% full scale value ±35 words (AC) ±0.5% full scale value ±35 words (AC)
Basic range (direct input) AC200mV-500V AC200μA-5A AC200mV-500V AC200μA-5A
Extended range (external input) AC transformer AC transformer
Frequency Range 45-400Hz AC 45-400Hz AC
Display method 0.56LED red (optional green. yellow or blue) 0.56LED red (optional green. yellow or blue)
Product Features Fully enclosed gray shell, flat design, screw-tight installation Fully enclosed gray shell, flat design, screw-tight installation
Others +/- polarity automatic conversion, optional reading lock function. Optional with RS-485 interface, upper limit, lower limit setting, with transmitter output function. +/- polarity automatic conversion, optional reading lock function. Optional with RS-485 interface, upper limit, lower limit setting, with transmitter output function.
 product description5

 product description6

 product description7

 product description8

DC5V±5%≤100mA AC/DC9V-12V AC/DC24V-48V DC5V±5%≤100mA AC/DC9V-220V AC110-220V DC5V±5%≤100mA AC/DC9V-220V AC110-220V DC5V±5%≤100mA AC/DC9V-220V AC110-220V
74×32×69 9×48×77 96×48×86 95×.48×117
70×28 9×45 90×45 91×44
±0.03% of full scale value ±2 words (DC)±0.5% full scale value ±35 words (AC) ±0.03% of full scale value ±2 words (DC)±0.5% full scale value ±35 words (AC) ±0.03% of full scale value ±2 words (DC)±0.5% full scale value ±35 words (AC) ±0.03% of full scale value ±2 words (DC)±0.5% full scale value ±35 words (AC)
200mV/2V/20V /200V/500V 200mV/2V/20V /200V/500V 200mV/2V/20V /200V/500V 200mV/2V/20V /200V/750V
200mV/2V/20V /200V/300V 200mV/2V/20V /200V/500V 200mV/2V/20V /200V/500V 200mV/2V/20V /200V/750V
200μA/ 2mA/ 20mA/ 200mA/2A/ 5A 200μA/ 2mA/ 20mA/ 200mA/2A/ 10A 200μA/ 2mA/ 20mA/ 200mA/2A/ 10A 200μA/ 2mA/ 20mA/ 200mA/2A/ 15A
200μA/ 2mA/ 20mA/ 200mA/2A/ 5A 200μA/ 2mA/ 20mA/ 200mA/2A/ 10A 200μA/ 2mA/ 20mA/ 200mA/2A/ 10A 200μA/ 2mA/ 20mA/ 200mA/2A/ 15A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
0.56LED red (optional green. yellow or blue) 0.56LED red (optional green. yellow or blue) 0.56LED red (optional green. yellow or blue) 0.56LED red (optional green. yellow or blue)
Fully enclosed idle ash shell, flat design, ejector clamp installation Fully enclosed gray shell, flat design, embedded installation Fully enclosed gray housing, flat design, screw-fastened installation Fully enclosed gray housing, flat design, screw-fastened installation
+/- polarity automatic switching. Optional reading locking function +/- polarity automatic switching. Optional reading locking function. Optional with RS-485 interface, upper and lower limit setting, with transmitter output function. +/- polarity automatic switching. Optional reading locking function. Optional with RS-485 interface, upper and lower limit setting, with transmitter output function. +/- polarity automatic switching. Optional reading locking function. Optional with RS-485 interface, upper and lower limit setting, with transmitter output function.

Recommendation: The digital AC ammeter is in the measurement range of 10A-300A, and it is recommended to use a precision current transformer (see pages 49-51 for technical specifications). The production cost can be saved by 30%-50%.

3 and a half LED digital display meter

The main technical parameters

shape

 product description1

 product description2
working power supply

AC/DC9V-12V AC/DC24V AC-220V
(Two-wire direct measurement. No working voltage required)

AC/DC9V-12V AC/DC24V AC-220V
(Two-wire direct measurement. No working voltage required)

Dimensions (width x height x depth mm)

70×40×25

70×40×25
Mounting Hole(mm)

68×38

68×38

product description3

Suggestion: The digital AC ammeter is in the measurement range of 10A-300A. It is recommended to use a precision current transformer (see pages 49-51 for technical specifications), which saves 30%-50% in production costs.

Shape

 product description4

Working power AC220v
Dimensions (width x height x depth mm) 96×48×117
Mounting Hole(mm) 90×43
Measurement precision Main 0.2% full scale value ±2 words (DC). ±0.5% full scale value ±5 words (AC)

product description5


Product detail pictures:

ODM Digital Dc Voltmeter And Ammeter Factory - LED Digital Display Meter – Newlink detail pictures


Related Product Guide:

We emphasize progress and introduce new merchandise into the market each and every year for ODM Digital Dc Voltmeter And Ammeter Factory - LED Digital Display Meter – Newlink , The product will supply to all over the world, such as: Tanzania, Berlin, Kenya, If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us. We are looking forward to forming successful business relationships with new clients around the world in the near future.
  • Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
    5 Stars By Miranda from California - 2017.05.02 18:28
    Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.
    5 Stars By Honorio from Nicaragua - 2017.08.28 16:02
    Write your message here and send it to us

    Related products

    • OEM High Quality Thermal Overload Protection For Electric Motors Supplier - Intelligent Temperature And Humidity Controller – Newlink

      OEM High Quality Thermal Overload Protection Fo...

    • OEM High Quality Analog Dc Voltmeter Panel Mount Manufacturer - Active and Reactive Frequency Table (Design Paragraph) – Newlink

      OEM High Quality Analog Dc Voltmeter Panel Moun...

      Intelligent digital display Power Meter Instruction Manual Overview This series of intelligent digital display power meter is a high-precision meter developed for power measurement and display in power grid and automatic control system. It has the advantages of intuitive display, high precision, good stability and strong vibration resistance. CPU digital processing, AC true RMS measurement, CT (PT) can be set through the panel keys. Optional: 1 relay control output, can be set to: upper limit...

    • OEM High Quality Industrial Power Meter Factories - Three-Phase Ammeter (Conventional) – Newlink

      OEM High Quality Industrial Power Meter Factori...

      Overview The three-phase ammeter adopts the AC sampling technology to measure the true RMS value, and can measure the three-phase current in the power grid. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: Three-phase current Display: Three rows of L...

    • ODM Electric Prepaid Meter Supplier - Active and Reactive Frequency Table (Regular) – Newlink

      ODM Electric Prepaid Meter Supplier - Active a...

      Smart Frequency Meter Instruction Manual Product Features 1. The whole four-digit display 2. Optional with communication function, communication address, baud rate 3. Software adjustment, no internal potentiometer, high precision 4. Software adjustment, no internal potentiometer, high precision Matters needing attention 1. Before use, the meter needs to be powered on for 15 minutes. 2. Pay attention to prevent vibration and impact, and do not use it in places with excess dust and excess harmf...

    • ODM Voltmeter Digital Dc Suppliers - Digital LED Timer – Newlink

      ODM Voltmeter Digital Dc Suppliers - Digital L...

      Shape     working power supply A type DC5V ±5%S150mAAC/DC9-12V B type DC5V±5%≤150mA AC/DC9v-220V AC110-220V DC5V±5%≤150mA AC/DC9v-220V AC110-220V Dimensions (width × height × depth mm) 79×42.5×25.5(A)79×42.5×58(B) 74×32×69 Mounting Hole(mm) 76×39.5 70×28 Basic range Customized on request Customized on request Measurement precision ≤0.1% ≤0.1% Input Contact signal or standard TTL high and low level signal Contact signal or standard TTL high and low level signal Display method ...

    • OEM High Quality Hall Effect Amp Meter Factory - Three-Phase Ammeter (Conventional) – Newlink

      OEM High Quality Hall Effect Amp Meter Factory ...

      Overview The three-phase ammeter adopts the AC sampling technology to measure the true RMS value, and can measure the three-phase current in the power grid. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: Three-phase current Display: Three rows of L...