The incredibly abundant projects administration experiences and 1 to one provider model make the superior importance of small business communication and our easy understanding of your expectations for Motor Undervoltage Protection, 3 Phase Power Consumption Meter, Microwave Power Meter, We are going to provide most effective quality, quite possibly the most current market aggressive rate, for each and every new and outdated consumers with the most great environmentally friendly solutions.
ODM Dc Current Ammeter Supplier - Active and Reactive Frequency Table (Design Paragraph) – Newlink Detail:

Intelligent digital display Power Meter Instruction Manual

Overview

This series of intelligent digital display power meter is a high-precision meter developed for power measurement and display in power grid and automatic control system. It has the advantages of intuitive display, high precision, good stability and strong vibration resistance. CPU digital processing, AC true RMS measurement, CT (PT) can be set through the panel keys. Optional: 1 relay control output, can be set to: upper limit; lower limit; upper and lower limit, 2 digital output, RS485 communication interface, using standard Modbus-RTU protocol, can be directly connected with industrial configuration software, easy to group network, 3. All the way analog output.

product-description1

product-description2

Operating Instructions

1. key definition

Function key SET: It is used to enter the menu, and it is the confirmation key in programming mode.

Shift key: Cycle through the nixie tubes in the selected page, and the selected nixie tubes are flashing.

Increase key ▲: Enter the setting value, change the value of the flashing digital tube (the numbers cycle from 0 to 9).

2. Operation method

Use the menu key SET to select the setting page, use the increase key ▲ to enter the setting value setting, use the shift key and the increase key ▲ to change the digital tube value on the page, adjust to the desired value and press the function key SET to confirm and exit the programming state.

Single/Three Phase Power Factor Meter Instruction Manual

Features

1. Single-phase and three-phase can be set through the panel buttons

2. Display range: C0.000~1.000~L0.000

3. Software adjustment, no internal potentiometer, high precision

4. Optional with communication function. (must be specified when ordering)

5. Optional with upper and lower limit alarm control function

Instructions

1. Press and hold the SET button for 6 seconds to enter the menu, the r-H (for setting direct reading parameters) mark appears, and then press SET again to enter the set value (0005), this value is the displayed value (ie the base value), this You can use the up key “△” to change the large value, and you can also use the down key “▽” to change the small value. Press the SET key again to display the r-K (set magnification) mark, and press SET again to enter the set value (0001). At this time, you can use the up key “△” to change the large value, and you can also use the down key “▽” to change the small value.

Note: If it is a simple function, after completing the operation through the above keys, press the SET key continuously to exit.

2. If you want additional functions, you can continue to complete the operation through the following keys:

Press the SET key again to display the Addr (communication address) sign, and press SET again to enter the set value (0001). At this time, you can use the up key “△” to change the large value, or use the down key “▽” to change the decimal value. Press the SET key again to display the BAUD (baud rate) mark, and press SET again to enter the set value (9600). At this time, you can use the up key “△” to change the large value, or use the down key “▽” to change the decimal value . Press the SET button again to display the ALHL (alarm) sign, press SET again to enter the upper limit alarm setting (AH-Y), if you want to set the lower limit alarm, you can press the up button “△” again to enter the lower limit alarm setting (AL-Y) ), then press SET to display the (ALN) sign, then press SET again to enter the alarm value setting menu (2000). At this time, you can use the up key “△” to change the larger value, or press the down key “▽” Change the decimal value.

Matters needing attention

1. Before use, the meter needs to be powered on for 15 minutes.

2. Pay attention to prevent vibration and impact, and do not use it in places with excess dust and excess harmful gases.

3. The input wire should not be too long. If the input end of the signal under test is long, please use a twisted pair shielded wire.

4. If the signal is accompanied by high frequency interference, a low frequency filter should be used in the line.

5. When not in use for a long time, please turn on the power for no less than 4 hours every three months.

6. Long-term storage should avoid direct light, and should be stored at -10℃~70℃.

7. If there is no display on the meter, first check the auxiliary power supply to see if the voltage is within the specified range.

8. If the display is abnormal, check whether the input signal is normal and whether the signal terminals are tightened.

9. Unless the PT has enough power, the PT signal cannot be used as an auxiliary power supply at the same time to ensure the normal operation of the instrument.

10. The screws of the current terminals in the CT circuit must be tightened to ensure reliable contact between the incoming and outgoing wires to avoid malfunctions.

11. To calibrate the instrument, the calibration instrument should be better than level 0.1 to ensure the calibration accuracy.

Product In Kind

product-description3

External Dimensions

product-description4


Product detail pictures:

ODM Dc Current Ammeter Supplier - Active and Reactive Frequency Table (Design Paragraph) – Newlink detail pictures


Related Product Guide:

It adheres on the tenet Honest, industrious, enterprising, innovative to acquire new solutions regularly. It regards shoppers, success as its very own success. Let us establish prosperous future hand in hand for ODM Dc Current Ammeter Supplier - Active and Reactive Frequency Table (Design Paragraph) – Newlink , The product will supply to all over the world, such as: Gabon, Brunei, Belgium, Providing the best products, the most perfect service with the most reasonable prices are our principles. We also welcome OEM and ODM orders.Dedicated to strict quality control and thoughtful customer service, we are always available to discuss your requirements and ensure full customer satisfaction. We sincerely welcome friends to come negotiate business and start cooperation.
  • In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
    5 Stars By April from Sheffield - 2018.12.22 12:52
    High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Cora from Argentina - 2017.01.11 17:15
    Write your message here and send it to us

    Related products

    • ODM Wireless Current Sensor Transmitter Manufacturers - Common Type Temperature And Humidity Controller – Newlink

      ODM Wireless Current Sensor Transmitter Manufac...

      Application

    • ODM High Current Dc Ammeter Factories - Single Phase Voltmeter (Conventional) – Newlink

      ODM High Current Dc Ammeter Factories - Single...

      Overview The smart voltmeter adopts AC sampling technology, can measure the voltage in the power grid, and can set the magnification through the panel buttons, which is very cost-effective. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: s...

    • ODM Inline Watt Meter Factory - Single-Phase Multi-Function Power Meter (Design Version) – Newlink

      ODM Inline Watt Meter Factory - Single-Phase M...

      Overview The single-phase multi-function meter can measure all the commonly used power parameters in the power grid system with high precision: single-phase voltage, single-phase current, active power, reactive power, power factor, grid frequency, active energy, reactive energy, and with communication Interface and energy pulse output function. Adopt MODBUS-RTU communication protocol to realize LED/LCD on-site display and remote RS-485 digital communication. It has the characteristics of conv...

    • ODM Wall Outlet Power Meter Manufacturers - LED Digital Display Meter – Newlink

      ODM Wall Outlet Power Meter Manufacturers - LE...

      ltem/Model (Emerald Backlight) (white backight optional negative display white characters) Shape     Working power DC5V±5%≤15mA AC/DC9V-12V AC/DC24V DC5V±5%≤15mA AC/DC9V-12V AC/DC24V Dimensions (WwH’Dmm) 79×42.5×25.5 79×42.5×25.5 Mounting hole(mm) 75×39.5 75×39.5 Measurement accuracy ±0.2% of full scale value ±2 words(DC) +0.5% full scale value ±5 words (AC) ±0.2% of full scale value +2 words(DC) ±0.5% full scale value 15 words(AC) Basic rangeo DC voltage (direct inpu...

    • OEM High Quality Single Phase Motor Overload Protection Factories - Intelligent Temperature And Humidity Controller – Newlink

      OEM High Quality Single Phase Motor Overload Pr...

      Application

    • OEM High Quality Voltmeter Dc Digital Factories - Three-Phase Voltage And Current Combination Table (Conventional) – Newlink

      OEM High Quality Voltmeter Dc Digital Factories...

      Overview The three-phase voltage and current combination meter is a multi-functional electrical measuring instrument with programmable measurement, display and digital communication functions. It can complete electricity measurement, data display, acquisition and transmission, and can be widely used in substation automation, distribution automation, intelligent buildings , Electric energy measurement, management and assessment within the enterprise. The measurement accuracy is 0.5 level, and ...